What Are RCRA Waste Codes?
RCRA waste codes are the alphanumeric identifiers EPA assigns to hazardous wastes. Every hazardous waste carries at least one, the code goes on your container label, your waste profile, and your manifest, and it determines how the waste has to be treated and disposed of.
There are two ways a waste gets a code. Either it appears on one of EPA’s four lists — the F, K, P, and U lists — or it exhibits one of the four hazardous characteristics, which assigns a D code. A single waste can carry several codes at once, and often does.
Assigning the code is part of your hazardous waste determination, which is a legal obligation under 40 CFR 262.11 that falls on you as the generator. This page is the reference for the codes themselves. The determination page covers the process for getting there.
Characteristic Codes — The D List
If a waste isn’t on one of the four lists, you evaluate it against the four characteristics in 40 CFR Part 261 Subpart C. Any single one makes it hazardous.
D001 — Ignitability. A liquid with a flash point below 140°F. Also non-liquids capable of spontaneous combustion, ignitable compressed gases, and oxidizers. Flash point is established by closed-cup testing, Pensky-Martens or Setaflash.
D002 — Corrosivity. An aqueous waste with pH at or below 2, or at or above 12.5. Also liquids corroding steel faster than 6.35 mm per year at 55°C.
D003 — Reactivity. Unstable material, waste reacting violently with water, forming explosive mixtures with water, generating toxic gases on contact with water, or capable of detonation. Also cyanide- and sulfide-bearing wastes that generate toxic gas between pH 2 and 12.5.
D004 through D043 — Toxicity. Determined by the Toxicity Characteristic Leaching Procedure, SW-846 Method 1311. TCLP simulates landfill conditions and measures whether any of 40 constituents leach above its regulatory limit.
The eight TCLP metals, which are the codes most generators encounter:
| Code | Constituent | TCLP limit (mg/L) |
|---|---|---|
| D004 | Arsenic | 5.0 |
| D005 | Barium | 100.0 |
| D006 | Cadmium | 1.0 |
| D007 | Chromium | 5.0 |
| D008 | Lead | 5.0 |
| D009 | Mercury | 0.2 |
| D010 | Selenium | 1.0 |
| D011 | Silver | 5.0 |
D012 through D043 cover pesticides, herbicides, and organic compounds — benzene (D018), methyl ethyl ketone (D035), tetrachloroethylene (D039), and trichloroethylene (D040) among the more common.
F-List — Wastes From Non-Specific Sources
The F list covers wastes from common industrial and manufacturing processes, regardless of what industry you’re in. Codified at 40 CFR 261.31.
Spent solvents — F001 through F005. These are the F codes most facilities encounter.
- F001 — spent halogenated solvents used in degreasing: tetrachloroethylene, trichloroethylene, methylene chloride, 1,1,1-trichloroethane, carbon tetrachloride, chlorinated fluorocarbons
- F002 — spent halogenated solvents from other uses, including chlorobenzene, ortho-dichlorobenzene, trichlorofluoromethane, and 1,1,2-trichloroethane
- F003 — spent non-halogenated solvents: xylene, acetone, ethyl acetate, ethyl benzene, ethyl ether, methyl isobutyl ketone, n-butyl alcohol, cyclohexanone, methanol
- F004 — cresols, cresylic acid, nitrobenzene
- F005 — toluene, methyl ethyl ketone, carbon disulfide, isobutanol, pyridine, benzene, 2-ethoxyethanol, 2-nitropropane
F003 is the one worth knowing in detail. It’s listed solely for ignitability, not toxicity. Under 40 CFR 261.3(g), a waste listed only because it exhibits a characteristic can be excluded from regulation once it no longer exhibits that characteristic. That exception does not apply to F001, F002, F004, or F005, which are listed for toxicity.
Other F codes:
- F006 through F012, F019 — electroplating, metal heat treating, and chemical conversion coating
- F020 through F023, F026 through F028 — dioxin-bearing wastes
- F024, F025 — chlorinated aliphatic hydrocarbon production
- F032, F034, F035 — wood preserving, covering creosote, pentachlorophenol, and inorganic preservatives
- F037, F038 — petroleum refinery separator sludge and float
- F039 — multi-source leachate
K-List — Wastes From Specific Industries
The K list is source-specific: these codes apply only if you operate in one of thirteen named industries. Codified at 40 CFR 261.32.
Wood preservation, inorganic pigment manufacturing, organic chemicals manufacturing, inorganic chemicals manufacturing, pesticide manufacturing, explosives manufacturing, petroleum refining, iron and steel production, primary aluminum production, secondary lead processing, veterinary pharmaceuticals manufacturing, ink formulation, and coking.
If you’re a healthcare facility, a laboratory, or a general manufacturer, the K list almost certainly doesn’t apply to you.
P-List — Acutely Hazardous Commercial Chemical Products
The P list, at 40 CFR 261.33(e), covers discarded commercial chemical products EPA classifies as acutely hazardous. These carry the tightest thresholds in all of RCRA.
Generating more than 1 kilogram per month of acute hazardous waste makes you a large quantity generator, regardless of your total hazardous waste volume. A single discarded container can change your generator category and with it your accumulation limits, training obligations, and reporting requirements.
P codes healthcare facilities encounter:
| Code | Substance |
|---|---|
| P001 | Warfarin, greater than 0.3% |
| P012 | Arsenic trioxide |
| P042 | Epinephrine |
| P046 | Phentermine |
| P075 | Nicotine |
| P188 | Physostigmine salicylate |
| P204 | Physostigmine |
One important clarification on P042. EPA has stated that epinephrine salts — the form in most pharmaceutical preparations — are not P042. The listing applies to epinephrine itself. This distinction has caused a great deal of unnecessary P-listed waste over the years, so it’s worth confirming the exact form before you code it.
The P and U lists apply to unused commercial chemical products — the sole active ingredient, off-spec material, spill residue, or container residue. A drug that was administered to a patient is generally evaluated differently. Our breakdown of what goes in the black bin covers the pharmacy side in practice.
U-List — Toxic Commercial Chemical Products
The U list, at 40 CFR 261.33(f), covers discarded commercial chemical products that are toxic but not acutely hazardous. No 1-kilogram threshold applies.
Common U codes in healthcare and laboratory settings:
| Code | Substance |
|---|---|
| U010 | Mitomycin C |
| U035 | Chlorambucil |
| U044 | Chloroform |
| U058 | Cyclophosphamide |
| U059 | Daunomycin |
| U089 | Diethylstilbestrol |
| U129 | Lindane |
| U150 | Melphalan |
| U151 | Mercury |
| U200 | Reserpine |
| U206 | Streptozotocin |
| U237 | Uracil mustard |
| U248 | Warfarin, 0.3% or less |
Nine chemotherapy agents are RCRA-listed: arsenic trioxide (P012), chlorambucil (U035), cyclophosphamide (U058), daunomycin (U059), diethylstilbestrol (U089), melphalan (U150), mitomycin C (U010), streptozotocin (U206), and uracil mustard (U237). Bulk waste of these is hazardous waste, not trace chemotherapy waste — a distinction that changes which container it belongs in. Our guide to what goes in the yellow bin covers where the line falls.
How to Find the Code for Your Waste
The practical sequence:
1. Check whether it’s a discarded commercial chemical product. If you’re disposing of an unused chemical, drug, or off-spec product, search the P and U lists by chemical name first. The lists are indexed by the sole active ingredient.
2. Check your process against the F list. Spent solvents from cleaning or degreasing are the most common hit. The F codes are driven by what the solvent is and what it was used for.
3. Check the K list only if you’re in one of the thirteen industries. Otherwise skip it.
4. Evaluate the four characteristics. This applies even if you already found a listed code, because a waste can carry both. A spent ignitable solvent may be F003 and D001.
5. Add state codes. States running authorized RCRA programs may assign additional codes, and these are the ones most often left blank on a waste profile.
You can determine codes from knowledge — safety data sheets, process knowledge, prior analytical data — rather than testing every stream. 40 CFR 262.11(d) permits it explicitly. You do have to document the basis.
A Waste Can Carry Multiple Codes
This trips people up regularly. There’s no single correct code for most wastes; there’s a complete set.
A spent xylene solvent is F003 for the listing and D001 for ignitability. A corrosive waste containing chromium is D002 and D007. Each applicable code must appear on the label, the profile, and the manifest, because each one carries its own treatment standard under the land disposal restrictions.
Omitting a code isn’t a paperwork error. It can mean the receiving facility treats the waste by a method that doesn’t satisfy the standard for the constituent you left off.
The Mixture Rule — Codes Carry Forward
Under 40 CFR 261.3(a)(2)(iv), a mixture of a listed hazardous waste and any solid waste is itself a listed hazardous waste, and the listing applies to the entire volume.
A pint of F005 solvent poured into a 55-gallon drum of non-hazardous material produces 55 gallons of F005. The listing does not dilute.
This is why the determination has to be made at the point of generation, before anything is combined, and why intentional dilution to escape a characteristic is impermissible treatment rather than a clever workaround.
For characteristic wastes the rule works differently: a mixture is hazardous only if the resulting mixture still exhibits a characteristic.
The Derived-From Rule — Residues Keep the Code
Under 40 CFR 261.3(c)(2)(i), any solid waste generated from the treatment, storage, or disposal of a listed hazardous waste is itself hazardous and carries the same code.
Incinerator ash from burning a listed waste is a listed waste. Sludge from treating a listed wastewater is a listed waste. Spill residue, contaminated soil, and used absorbent all inherit the code.
This is the mechanism behind cradle-to-grave liability — the code follows the material through every transformation, which is why your responsibility doesn’t end at the dock. We cover the liability side in cradle to grave: what does that mean.
Exemptions to the Mixture and Derived-From Rules
Both rules have exceptions, and they matter because they’re the difference between managing a few gallons as hazardous waste and managing thousands.
The main categories:
De minimis losses to wastewater treatment. 40 CFR 261.3(a)(2)(iv)(A) through (G) exempt small losses of specific commercial chemical products and listed wastes to a facility’s wastewater treatment system, subject to conditions on the type of material and the discharge permit.
Wastes listed solely for a characteristic. Under 261.3(g), a waste listed only because it exhibits a characteristic stops being regulated once it no longer exhibits it. F003 is the common example.
Specific wastewater exemptions tied to particular industries and processes.
Spent solvent mixture conditions governing when a solvent-bearing wastewater does and does not carry the F listing.
Each exemption is conditional, and claiming one you don’t qualify for is worse than not claiming it. Document the basis for any exemption alongside your determination records.
Frequently Asked Questions
What are the RCRA waste codes? Alphanumeric identifiers EPA assigns to hazardous wastes. F, K, P, and U codes come from EPA’s four lists of hazardous wastes; D codes are assigned when a waste exhibits ignitability, corrosivity, reactivity, or toxicity.
What is the difference between P-listed and U-listed waste? Both cover discarded unused commercial chemical products. P-listed wastes are classified as acutely hazardous and carry a 1 kilogram per month threshold that triggers large quantity generator status. U-listed wastes are toxic but not acutely hazardous and have no equivalent threshold.
What are the four characteristics of hazardous waste? Ignitability (D001), corrosivity (D002), reactivity (D003), and toxicity (D004 through D043). Any one makes a waste hazardous.
Can a waste have more than one RCRA code? Yes, and most do. A spent ignitable solvent can be both F003 and D001. Every applicable code has to appear on the label, profile, and manifest, because each carries its own treatment standard.
What is the mixture rule? Mixing a listed hazardous waste with any solid waste makes the entire resulting volume that listed waste. The listing does not dilute.
What is the derived-from rule? Any waste generated from treating, storing, or disposing of a listed hazardous waste is itself hazardous and carries the same code. Ash, sludge, and treatment residues all inherit the listing.
Where do I find the official RCRA waste code lists? 40 CFR Part 261 Subpart D holds the F, K, P, and U lists. Subpart C holds the characteristics. State programs may assign additional codes beyond the federal set.
Do I need lab testing to assign a waste code? Not necessarily. 40 CFR 262.11(d) permits determination by applying knowledge of the waste in light of the materials and processes involved. Testing is for genuinely uncertain or mixed material.
Need Help Coding a Waste Stream?
TriHaz Solutions provides hazardous waste disposal for healthcare facilities, laboratories, and industrial generators across Alabama, Tennessee, and the Southeast — including waste stream profiling and lab packing for unknowns and accumulated chemicals.
If you have streams you’ve never formally coded, or a storage area full of containers nobody can identify, that’s a conversation worth having. Once the codes are right, container labeling and accumulation limits follow from them.
How to Tie a Red Bag: Watch the Video
How NOT to Tie a Red Bag: Watch the Video
SUBSCRIBE TO OUR BLOG
Simplify your job and stay up-to-date on medical and hazardous waste compliance for healthcare and industry.
By subscribing to our blog you agree to our Privacy Policy.